7.4 Fuel burning water heater is not allowed in bedroom or bathroom unless direct vent type or complying with CPC 504.1. On larger complexes, the law allows for 15% of the respective elements to be inspected as a representative sampling. 812 - Rural County Road, Driveway and Private Road Intersections 815 - Rural Driveway / Roadway 816 - Rural Driveway Drainage, Ditches 818 - Rural Driveway Drainage, Valley Gutters 820 - Rural Driveway Drainage, Culverts Design 900A - Rural Typical Road Cross-Sections 900B - Urban Typical Road Cross-Sections (R317.1) Hardware and fasteners shall be hot-dipped galvanized, stainless steel, silicon bronze, or copper. Who Performs Inspections? Tables for the minimum joist spansin California's moderate climate regions, How we build a closed in riser stair for decks with a skirt for solid railings, Deck stair total rise table with calculations for riser heights and number of treads, This page last modified on Thursday, February 03, 2011, Alter Eagle
(CMC 903.2.3). Custom built deck for a corner of the yard. An added beam allows independent movement of the deck, natural expansion and contraction and no possibility of trapped moisture damaging your home over the many years our decks last. At their meeting on November 2, 2022, the Sonoma City Council adopted an ordinance amending and adopting the 2022 California Building Standards Code. Various cable rail configurations are often proposed to minimize the rail system's impact on the view from the deck. Inspections will be performed on any external building element six feet above ground level including walkways, balconies, decks, landings, stairways and railings. Inspectors have voice mail if you are unable to reach them in the office. The decking span you choose will effect the feel and potentially the safety of your deck. Lag screws must go through band board at least 1/2 ". The span table used in our area for 2011 is the UBC 1997 code (left) for the minimum size of joists for decks. 2035) Chapter 7. (R703.3.3), 4.8 Corrosion resistant flashing shall be provided at openings and intersections/attachments. You need a permit to build a deck if it is: More than 18 inches above the ground A roof deck (built on top of part of the building) In an environmentally critical area (ECA), for example landslide-prone areas. (May still require a site plan.). 13.6 Dwelling units in two-family dwellings shall be separated from each other by wall and floor assemblies having not less than a 1 hour fire-resistance rating. 2000 LB/sq.ft. Rather, there are sections of the Residential CodeThat Apply to building standards related to structures such as railings, stairs, stringers, treads, footings, framinand ledger boards . What that does is gives us a rigid stair and a firm connection to the railing which in normal conditions can loosen over time. 2022 County of Sonoma. How to Build a Deck in HOA Community. Thirty-six inches is the most common residential height, but some jurisdictions vary. COUNTY OF SONOMA SUMMARY REPORT Agenda Date: 8/18/2020 . Decks under 30": Wetypically use a 8" dia x 8" thick footing with 4x4 P.T. The balustrade must be able to withstand 200 pounds of. See CRC for exceptions. Design / Build. Depending on location, this authority could include the fire marshal, building inspector, accessibility reviewer, and several other groups or agencies. Trim | Cabinets | Mantels, Deck Contractor
7.16 Roof construction and covering shall comply with R905 and local ordinance. We're only 65 miles north of San Francisco on Hwy. . BUILDING REGULATIONS Chapter 7A. With a header to the house and the deck was built 6, I'm putting a swim spa into an inground concrete bunker and will build a deck around it. The city will tell you right up front what the setbacks from property lines or sidewalks are. Once the deck assembly is completed, building authorities will make sure you meet code before a permit is issued. Definitions. For information on Building Design Assistance, go here. Width shall be 36 inches minimum. 3.9 Minimum size of concrete footings for exterior decks shall be in accordance with CRC Table R507.3.1, based on the tributary area of the footing and an assumed bearing capacity of soil of 1500 pounds per square foot, unless a higher bearing capacity has been justified by a geotechnical report. LPG appliances shall not be installed in an above grade underfloor space or basement unless such location is provide with an approved means for removal of unburned gas (CMC 303.7.1), 7.3 Provide combustion air for all gas fired appliances. 3315 3, 2000: Ord. Minimum 36 at all points above the permitted handrail height, Minimum 31.5 "width below handrail height where handrail is on one side, Minimum 27 "width below handrail where handrails are on both sides, Maximum rise of 7-3 / 4 - maximum difference among risers 3/8", Minimum tread width of 10 "- maximum difference among treads 3/8". Building codes are in place to ensure safety, and virtually every state and municipality enforces codes for deck construction. Decks building codes - Footings - IRC & IBC IRC R403 & IBC 1805 Footings Footings shall be supported on undisturbed natural soils or engineered fill. (R303.3.1), 2.5 Provide ventilation for products of combustion to outside air. Tempered windows 2. Well & Septic, Use, or Zoning).More Information:When Is a Building Permit Not Required? 2.11 All habitable rooms except kitchens shall be at least 70 square feet in area and shall have a width of at least 7 feet. For just the permit. (R806.2) Unvented attics may be allowed if meeting the requirements of R806.5. (CPC 608.3) Provide seismic strapping or anchorage resisting overturning of water heater. Note size, number and position of crawl space vents. According to the California Building Standards Code, no building or structure may be erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted, or demolished unless a separate . . The bottom of the clear opening shall be no more than 44 inches from the floor (R 310.1). Plates at intersections with bearing walls and corners shall also be overlapped. Get Quotes and Book Instantly. 4.3 Weatherproofing of exterior surfaces above and below grade is required. That will show in your new deck. Now that you know how high you have to build your railings, follow up by reading these other more detailed discussions on style and design ideas. Items to be considered at earliest possible stage of project development which could affect project: Upload the digital plan file and separate files of all supporting documentation such as structural calculations, energy compliance forms, soil reports, etc. Authorities say a man who reportedly shot at people in California's wine country killed himself Friday after a car chase. Building Code. A variance is a rarity. Sand, silty sand: Finer silt particles will take fifteen minutes to an hour to settle. The vertical bar shall extend to 3 inches clear from the bottom of the footing, have a standard hook, and extend a minimum of 14 inches into the stem wall. RESIDENTIAL DECKS INFORMATION GUIDELINE 9 CITY OF ESCONDIDO BUILDING DIVISION 201 N. BROADWAY, ESCONDIDO, CA 92025 (760) 839-4647 . Limited vents in foundation, eves and soffit 3. Include the size, spacing and grade of all members. Locate upper and lower bolts maximum 5.5 "/ 6.5" / 7.5 "apart vertically for 2x8 / 10/12 respectively. "Building Official" means the Chief Building Official as defined in Section 7-2 of the Sonoma County The concrete mix design shall address bleeding, shrinkage, and curling, in accordance with ACI 302.2R-06. learn more about building decks from builders and people like you. Find out WHAT the irc says about building code requirements for decks. Penalties, Violations and Abatement. Welive in the beautiful wine country of Northern California, it just doesn't get much better than this. (Table R602.3), 10.5 Sole plate to joist or blocking shall be 16d common nails at 16 inches on center and 2-16d common nails at 16 inches at braced wall panels. (R302.3), Subdivisions and Survey for Engineers and Surveyors, 2022 California Green Building Standards Code (CalGreen), Land use limitations County zoning ordinances, contact Planning Division, Geologic hazards Landslides, geotechnical (soils) report. Solar Permits for Residential Rooftop Systems. Building Permits. viii To ensure your design meets code, confer with the Authority Having Jurisdiction (AHJ) over your project. There are usually limits to how close your deck can be to another building. Simple projects that do not require a building permit. (Ord. Pro Tips on Building a Code-Compliant Deck By Rob Robillard. Cripple walls less than14 inches in height shall be continuously sheathed or constructed of solid blocking. The IRC deck joist span table Serving North Marin & West Sonoma Counties in the San Francisco North Bay area of Northern California 1200112028), shall retain the authority to promulgate and enforce this plumbing code and to make any changes it deems necessary if the changes meet the Uniform . The plan set shall also include an applicable Site Plan, single-line diagram, and appropriate signage details. (Table R602.3) Nailing shall be inspected prior to covering. Ordinance No. Except when located more than 5.5 feet above the floor or when part of a luminaire or appliance. Building & Construction, How to Cut & Install
Your selection of decking material will determine the maximum spacing of your joist. They review projects inside and out to make sure they are built according to the approved plans and building codes. 9.6 Provide detail of connection of floor girder at foundation wall. Adding a 8x10 deck attached to existing deck, 2x10's, I won an inflatable 6 person inter hot tub. 2.6 Attic ventilation: 1/150 of attic area. If a Class I vapor retarder is used the ratio may be reduced to 1/1500. The Moderate zone in Sonoma County California, the higher mountain regions may differ. but most building dept. I have been advised to keep the deck joists a minimum of 6 inches. Make sure your project does not extend into those areas. The concrete 2,500 psi compressive. There are several resources about lead poisoning and prevention. Hire the Best Deck Builders in Sonoma, CA on HomeAdvisor. Limitations on deck materials and construction 5. It's usually pretty easy to recognize. Deck framing shall be positively attached to building framing at a minimum of 2 locations within 24 inches of each end of the deck with hold-down tension devices having an allowable design capacity of not less than 1500 pounds each, or at a minimum of 4 locations with hold-down tension devices of not less than 750 pounds allowable design capacity. 9.2 Joists under and parallel to bearing partitions shall be doubled. Avoid a bouncy, soft deck. A freestanding deck in your backyard may give you a chance to relax away from the house and the distractions inside so you can simply enjoy the scenery. The IBC requires 42" high guardrails. Permit Sonoma issues over-the-counter permits for work on existing pre-1978 buildings that may contain lead hazards. USGSGeologic Hazards - Spectral Response Acceleration Maps. Design / Build, Website Design by Owner
Secondary roof drains shall be provided not less than 2 inches above the roof surface (CPC 1101.12), 5.1 Common wall between garage and dwelling shall have inch gypsum board applied on the garage side. For foundation requirements of concrete and masonry wall construction, see Table 403.1(3). The minimum height of the railing varies based on the height of the deck. Before you can use the Deck Post Size Table in a meaningful way you have to understand the loads that your deck must withstand. (R312). Everyone wants the investment they put into their deck to last. Print job title or description, address and assessors parcel number and drawing index on the cover sheet. 13.5 Structures which are subject to Fire Safe Standards and located in the SRA , shall have a minimum 1-hour fire-resistance rating at exterior walls and the underside of exterior projections within 10 feet from an adjacent property line. 7.7 Showers and tubs with showers require a non-absorbent surface up to 72 inches above the floor. 8.1 Concrete shall be 3,000 pounds per square inch minimum for foundation and retaining walls (including stem walls), garage floor slabs, and porches or steps exposed to weather and 2,500 pounds per square inch minimum for all other concrete. All documents must be digitally sealed, signed, and dated by the person responsible for preparing them. For a residential deck, the code requires it be designed to support a minimum 40-psf live load. Exterior wall projections less than 2 feet from an adjacent property line are not allowed. All braced walls and conventional bracing shall be adequately labeled and dimensioned. Find out exactly how many balusters or pickets you need with a single click. Vent length shall be 14 feet maximum and the vent diameter shall not be less than 4 inches. Deck framing shall be positively attached to building framing at a minimum of 2 locations within 24 inches of each end of the deck with hold-down tension devices having an allowable design capacity of not less than 1500 pounds each, or at a minimum of 4 locations with hold-down tension devices of not less than 750 pounds allowable design capacity. 1-9 Building Codes & Ordinances 1-10 Building Code Design Requirements . (R314.4 & R315.7), 6.10 When alterations, repairs, or additions require a permit, smoke alarms shall be installed where required in new dwellings. Gridlines shall be provided corresponding to the lateral load resisting gridlines identified as required in Section 1.7 below. One opening shall be placed within 3 feet of each building corner. 2.2 Every sleeping room and any basement must have at least one openable window or door approved for emergency rescue with a minimum net clear opening of 5.7 square feet, except the windows at the grade floor shall have a minimum net area of 5.0 square feet. Hard costs: Building structures. Residential PSF Deck Requirements. Building a deck on or near a septic tank is not the best idea and can result in a damaged or punctured tank. (R506.2.3.1 & CalGreen 4.505.2.1), 4.6 The ground adjacent to the foundation shall be sloped so that the grade shall fall a minimum of 6 feet within the first 10 feet. BPC-005, If a construction project is revised, for example by altering floor plans or adding additional square footage, the, revisions must be reviewed and approved by Permit Sonoma. I calculate the loads put on the deck and use a span and size of framing higher than the recommended for code. All rights reserved. 1.10 Calculations: Provide engineers or architects design calculations for engineered plans. (CEC 445.18 & PG&Es Green Book), 7.1 Provide pressure relief valve with drain to outside for water heater. 11.3 Where ceiling joists or rafter ties are not provided trusses shall be used or engineering shall be provided. Decks over 30": We would calculate the tributary loads (including the spa load if any from the manufacturer) and size the footingfor the soil type. A landing is not required at doors other than the required egress door where a stairway of two or fewer risers is located on the exterior of the door, and the door does not swing over the stairway. The building inspectors are generally in the office between 8-8:30AM and 4:00-4:30PM. The height of the post shown in MRC Table R507.4 is measured from the underside of the beam to the top of the footing. Attachment methods vary depending on the style of stairs but this is a very common and reliable technique. California is the one exception where they Require 42 "guards. 10.8 Provide one layer of number 15 asphalt felt or other approved material under exterior siding. 2501. Show elevations, flashing, and anchorage. Learn more about IRC building codes for decks at Decks.com! . Disability Access Requirements and Resources(PDF: 115kB). (CEC 210.52F), 6.3 Kitchens and dining areas must have a minimum of two 20 ampere circuits. In either case, you are allowed to build taller guardrails as long as they conform to all other requirements stated in the code. A lockable means of disconnect must be installed, per applicable PG&E requirements. Deck ledgers shall be minimum 2x8 pressure-preservative-treated No. Chapter 7 of the Sonoma County Code is hereby amended as follows: (a) Section 7-3, Local appeals board and housing appeals board is revised to read: Sec. Decks (deck surfaces, stair treads/risers, porches, and balconies): Specify heavy timber (minimum 3 nominal thickness) OR exterior fire-treated wood OR non-combustible materials OR ignition resistant meeting SFM 12-7-A, parts A and B OR material that passes the SFM 12- 7-A (Part A only) and the (CMC 304.4; R807.1) In attics in which an appliance is installed, an opening and passageway at least as large as the largest component of the appliance shall be required. Learn how to trace the number and size of rises and runs to cut out your stair stringer. SONOMA COUNTY ANIMAL REGULATION ORDINANCE Chapter 6. Phone: (707) 784-6765. Kitchen counter outlets must be installed in every counter space 12 inches or wider, not greater than 4 foot on center and within 24 inches of the end of any counter space. HEIGHT DIAGRAMS: US and Canada. Garage to dwelling unit separation is not a rated firewall. For decks, we can review your plans and issue a permit on the spot if the design meets the required codes. Wall assemblies shall extend from the foundation to the underside of the roof sheathing, although wall assemblies need not extend through attic spaces where the ceiling is protected by not less than 5/8 inch Type X gypsum board, an attic draft stop is provided above and along the wall assembly separating the dwellings, and the structural framing supporting the ceiling is protected by not less than inch gypsum board or equivalent. 1.4 Foundation Plan: Completely dimension plan including interior footings. Lead Hazard Warnings on Pre-1978 Buildings. Look Up Property Information. (CEC 210.52), 6.4 GFCI outlets are required for all kitchen receptacles that are designed to serve countertop surfaces, in bathrooms, in underfloor spaces at or below grade level, in exterior outlets, in laundry areas, and in all garage outlets not dedicated to a single device or appliance. For foundation requirements for light frames walls with brick veneer, see Table R403.1(2). Listen in and see if it is a good solution for your next project. There are two types of building permits: But in some cases, a building permit is not required: Simple projects that do not require a building permit. Sections 8-11 address building structural design and are applicable to non-engineered structures and non-engineered elements of partially engineered structures. Show roof rafters and ceiling joists. When Is a Building Permit Not Required? 100 - Recommended Abbreviations, Lines, Symbols, 214 - Edge Grind Detail Transverse Conform Typical Section, 216 - Bus Stop Turnout Typical Section (Urban), 219B - Trench Backfill and Paving Details, Standard Improvement Plan Construction Notes, 222 - Weakened Planes, Score Marks and Expansion Joints, 223 - Curb, Gutter and Sidewalk Expansion Joint, New to Exist, 224 - Pedestrian Ramps, Location Overview, 224A - Curb Ramp Exceptions and Supplemental Requirements to State Standard Plans A88A and A88B, 226 - Typical Sidewalk Obstruction Transition, 305 - VLOC Single and Multiple Mailbox Assemblies, 306 - Mailbox Installation with Wooden Post, 402 - Storm Drain Outlet Rock Slope Protection, 600 - Pull Box Installation, No. California's green building standards code. 13.1 New structures, and remodels and additions to existing structures shall meet the requirements of the Permit Sonoma Planning Division based on parcel specific zoning, use, and setback requirements. So we have lots of help for you to learn how deep to dig, how large a footing should be based on load and soil capacity, how to connect hardware to the pier AND we talk about floating or free standing decks. Reviews construction plans prior to issuance of a building permit to ensure the project will conform to the uniform construction codes (building, electrical, plumbing, and mechanical) and sound engineering practices. (R502.4). 1st deck RAILINGS WHAT YOU NEED TO KNOW 36 "minimum height when surface is 30" + above grade We do not use pre-manufactured blocks sitting on dirt ora small amount of concrete. (CMC Chapter 7). (R408.2), 2.9 Heating system is required to maintain 68 degrees at 3 feet above floor level and 2 feet from exterior walls in all habitable room. Anything lower than 30" is often considered a patio or "porch deck," and a permit is typically not required. Rules and Regulations. - Local appeals board and housing appeals board. Fire-resistance rated floor/ceiling assemblies shall extend to the exterior walls, and the supporting construction shall have an equal or greater fire-resistance rating. The city will tell you right up front what the setbacks from property lines or sidewalks are. Indicate finished and existing grade elevations, i.e. Provide adequate identifications of assumed braced wall lines for conventional bracing, and provide on the plans lateral load resisting gridlines, corresponding to the structural calculations, for engineered structures. uncut end embed in concrete to the footing at 24" deep due to the height restriction for the framing. Cripple walls exceeding 4 feet in height shall be framed of studs as required for an additional story. Call (707) 784-6765. The IBC code for structural design has some very specific requirements for deck stairs: Stair rails on decks should be between 34 inches and 38 inches high, measured vertically from the nose of the tread to the top of the rail. 3.8 Exterior deck support posts shall be cross-braced in two directions for lateral stability. The GFCI must be adjacent to the hot tub on an outside wall at least 5 feet from any hot tub . Well & Septic, Use, or Zoning). The space between the finished floor and the bottom rail must not exceed 4 inches. 1.12 The job address must be posted at the job site and at the county road, and the building location shall be staked prior to submitting for the permit application. (R802.8) Nail blocking to top plate with (3) 8d toe nails per block or provide clips. (R307.2). Chapter 7, Article IIof Sonoma County's Municipal Code outlines Building Regulations for the unincorporated area of this county. BUILDING REGULATIONS Article I. (R302.11), 3.6 There shall be a floor or landing at the top and bottom of each stairway. Wood columns shall not be less in nominal size than 4" x 4" IBC 2304.9.7 Column and post-end connections shall be fastened to resist lateral and net induced uplift forces. Learn the math and how to trace out the number and size of rises and runs to cut out your stair stringer. (R304/R305), 3.1 Required egress door shall be side hinged and have a minimum net clear width of 32 inches and a minimum height of 78 inches. 6.15 Energy Storage Systems (ESS) shall be designed and installed in accordance with CRC Section R328. Fences not over 6 ft. in height. The permit fee for most decks under 250 square feet is $75. Building Permit with Plan Check to Permit IssuanceView how long it took from application submission, to first review comments, to permit issuance during the previous month. 7.17 Storage use or placement of a fuel-burning appliance in an underfloor area may trigger the requirement for a 1/2 inch gypsum wallboard or 5/8 inch wood panel membrane on the underside of the floor-framing member. Resources available to assist with questions about the applicability of the CRC are, the CRC, the Permit Sonoma website, the California Building Standards Commission, and Permit Sonoma Plan Check staff members. 11.6 Wood structural panel sheathing, when designed to be permanently exposed in outdoor applications, shall be of an exterior exposure durability. Transportation and Public Works is now Sonoma Public Infrastructure - Website updates coming soon! 12.1 New construction and additions/alterations increasing a buildings conditioned floor area or volume shall comply with applicable provisions of CalGreen. The Pacific coast and the type of steel used :: There are grades used for pressure treated lumber. 4.1 Naturally durable wood or preservative treated wood, per AWPA U1, shall be required in the following locations (R317.1): 4.2 Exposed glulams shall be preservative treated, applied by the manufacturer, or made from naturally durable wood. Prefabricated structures not more than 500 square feet in area, constructed of light frame materials and covered with cloth or flexible plastic which has a thickness no greater than 5/1000 of an inch, accessory to a single family dwelling, with no associated electrical, plumbing, or mechanical equipment and the height above existing grade does (CalGreen 301.1.1). Building Division Building Policies & Procedures Building Policies & Procedures Note: Some policies & procedures may reference outdated code sections but the intent and interpretations remain valid. Wood structural panel roof sheathing exposed to the underside may be identified as Exposure 1. See Section R302.13 of the CRC for exceptions. 10.1 Show stud size, height, grade and spacing. Guardrails are required once the deck is 30 or more above grade. 12.3 Residential buildings undergoing permitted alterations, additions or improvements shall replace noncompliant plumbing fixtures with water-conserving plumbing fixtures. (R309.1 & R309.2), 5.4 Appliances and receptacles installed in garages and carports shall be located so that all burners and burner-ignition devices are located 18 inches minimum above the floor unless listed as flammable vapor ignition resistant. The piers need to be placed at a proper depth to the slope, (some require a soilsengineer). We use a deeper impregnated treatment called ground contact. Safety is important and something that should always supersede style. The California Building Standards Code is made up of 12 parts containing various construction codes consisting of building, residential, plumbing, mechanical, electrical energy, fire, historical . Rather, there are sections of the Residential CodeThat Apply to building standards related to structures such as railings, stairs, stringers, treads, footings, framin and ledger boards . A separate Grading Permit application is required if the project meets the criteria established by Chapter 11 of the Sonoma County Code. Provide adequate drainage information, e.g. Information from the Building Division to help you with your project covering accessibility, building, electrical, mechanical, and plumbing. AN ORDINANCE OF THE BOARD OF SUPERVISORS, COUNTY OF SONOMA, STATE OF CALIFORNIA, AMENDING THE OFFICIAL ZONING DATABASE OF THE COUNTY OF SONOMA, ADOPTED BY REFERENCE BY SECTION 26-02-110 OF THE SONOMA COUNTY CODE, BY RECLASSIFYING CERTAIN REAL PROPERTY FROM LC LG/GE1 RC 50 SR DISTRICT (S) TO THE K LG/GE1 RC . (R703.7.3). Provide a table justifying all braced wall lines complete with required and provided values for wind and seismic for the specified wall type. (R403.1.5), 8.6 Concrete slabs shall be 3.5 inches thick minimum. Wood siding, sheathing and wall framing on the exterior of the building having a clearance of less than 6 inches from the ground or less than 2 inches from a horizontal concrete surface. It works to develop and implement the Sonoma County General Plan, Local Coastal Program and other adopted Area Plans or Specific Plans. (R506.1), 8.7 Provide adequate setbacks from slopes greater than 33 percent gradient equal to half the height of the slope (need not exceed 15 feet) for an adjacent ascending slope surface, and one third the height of the slope (need not exceed 40 feet) for an adjacent descending slope surface. (R302.5.1), 5.3 Garage and carport floor surfaces shall be of approved noncombustible material. Provide curtain rod or approved enclosure material. SONOMA COUNTY, CALIFORNIA - MUNICIPAL CODE SUPPLEMENT HISTORY TABLE Chapter 1. Minimum ceiling height shall be 7 feet. We always use steel that is has two coats of zinc for the extra protection needed and our deck screws are anodized or in some cases stainless steel. (R311.7.6), 3.7 Guards shall be located along open sided walking surfaces, including stairs, ramps, landings, and decks, that are more than 30 inches above the floor or grade, measured at any point within 36 inches horizontally. Envision a town with the best qualities of turn-of-the century America, yet with the ambiance of a European countryside. Corrosion resistant flashing is required for connecting to wood framed buildings. (R802.2). This is all great information to learn before you start your big project. Dimension front, side and rear distances to property lines and between structures. Under the Building Code, all construction or work that requires a building permit shall be subject to inspection and approval by the County Building Inspector. We also solid block our decks which make them even more rigid. (CEC 210.52E), 6.5 Receptacles must be installed at 12 foot on center maximum in walls. Fire resistant exterior siding 4. Adopted 12/13/22. TheDeck Post Size Table will help you answer that question or learn more aboutloads for posts. (R308.4.5), 7.12 Wood burning appliances shall be EPA phase II certified in the Northern Sonoma County Air Pollution Control District. Granular, gritty texture. 1.6 Framing Plans: Identify framing members and sheathing for floor and roof & ceiling plans.